Catalog item
Request a quotePANEL,CONTROL,ELECTRICAL-ELECTRO
6110FSC
01NCB code
445-8474Item number
NIIN 01-445-8474
- Unit price
- $55,715.53
- Unit of issue
- EA
- Source of supply
- F06
- DEMIL code
- Q
Identification
- Item name code
- 39448
- PINC
- 0039448
- Criticality code
- X
- II
- 0
- DEMIL code
- Q
- DEMIL integrity code
- 3
- NIIN assigned
- 13-JUN-97
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- ESD/EMI code
- B
- IUID indicator
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-NOV-2022 | DF | C | F06 | EA | 0.0000 | $55,715.53 | 1 | U | 0 | T | --SVM-N | $0.00 | L |
| 01-JUN-2026 | DN | C | NRP | EA | 0.0000 | $45,656.00 | 1 | U | 0 | H | 7RKBAR2 | $6,522.00 | N |
Part numbers
Characteristics
| END ITEM IDENTIFICATION | C130J AIRCRAFT |
|---|---|
| PART NAME ASSIGNED BY CONTROLLING AGENCY | PANEL ASSEMBLY,PROPELLER CONTROL AND FADEC RESET |
| SPECIAL FEATURES | CONSISTS OF 1 PANEL, 8 TOGGLE SWITCHES, 2 SWITCHES |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | NIMSC | Date assigned | IMC | PICA | PICA LOA | SICA | SICA LOA | Auth collab | DSOR |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| VM01 | VM | 01-OCT-25 | VM | 81 | VM | |||||||
| YD01 | YD | 01-FEB-17 | YD | 81 | YD | |||||||
| ZA01 | ZA | 01-FEB-00 | ZA | 81 | ZA | |||||||
| ZC01 | ZC | 01-JUN-10 | ZC | 81 | ZC | |||||||
| ZF01 | ZF | 01-JUN-17 | ZF | 81 | ZF | |||||||
| ZE01 | ZE | 01-APR-22 | ZE | 81 | ZE | |||||||
| ZH01 | ZH | 01-MAY-17 | ZH | 81 | ZH | |||||||
| ZI01 | ZI | 01-APR-19 | ZI | 81 | ZI | |||||||
| ZK01 | ZK | 01-JUN-97 | ZK | 81 | ZK | |||||||
| ZR01 | ZR | 01-DEC-07 | ZR | 81 | ZR | |||||||
| ZS01 | ZS | 01-DEC-01 | ZS | 81 | ZS | |||||||
| ZT01 | ZT | 01-OCT-08 | ZT | 81 | ZT | |||||||
| FLL4 | DF | 3 | P | P | 01-MAY-01 | B | TL | 22 | TL TU | CN | ||
| NAL4 | DN | 3 | P | 2 | 01-MAY-14 | E | TL | 22 | KE | 8D | KE TU | CN |
Service data
Navy
- COG
- 7R
- SMIC
- KB
- IRRC
- AR
- SMCC
- 2
Air Force
- Budget
- S
- MMAC
- VM
- PVC
- N
- ERRC
- T
Freight
- ACTY CD
- QH
Packaging
Unit and preservation
| PICA SICA | PKG cat | Unpackaged weight | Unpackaged width | Unpackaged length | Unpackaged height | Unit of issue | TOS | Intermediate container qty | Method of preservation | Clng drying | Pres mat | Wrap mat | Cush dun | THK | Unit cont | PKG data source |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 62Z0 | 4.3000 | 0.600 | 0.500 | 0.700 | EA | 000 No intermediate container quantity specified (000) | 51 Watervaporproof bag, heat sealed, with desiccant | 1 Any suitable process that is not injurious to the item. | 00 No requirement | XX | XX | X | NR PPP-B-1672, Type I, vertical star cushioning in reusable box. | A | |
| S | ZZZ0 | 0.0000 | 0.000 | 0.000 | 0.000 | EA | B | 000 No intermediate container quantity specified (000) | GX Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by... | 1 Any suitable process that is not injurious to the item. | 00 No requirement | 00 No requirement | 00 No requirement | 0 Not applicable | NY NAVICP Drawing No. | A |
Unit pack
| PICA SICA | SPC MKG | Inter cont | UCL | Lvl A | Lvl b | Lvl c | Unit pack weight | UP SZ MAXB | UP SZ MAXL | UP SZ MAXH | Unit pack cube | OPI | Supplemental instructions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| P | 19 Method 50 reusable container | 00 No requirement. | B Unit container provides level B packing protection. | B | 9.5000 | 1.20000 | 1.20000 | 14.50000 | 1.3110 | M All packaging data is mandatory for compliance and no substitutions are permitted. | 6 UNITS OF DESICCANT | ||
| S | 39 ESD sensitive electronic device requirements of MIL-STD-129 apply | 00 No requirement. | A Unit container provides level A packing protection. | F Packing is not required: the unit container shall also serve as the shipping container. | F Packing is not required: the unit container shall also serve as the shipping container. | F Packing is not required; the unit container shall also serve as the shipping container. | 1.5000 | 10.00000 | 12.00000 | 3.00000 | 0.2080 | M All packaging data is mandatory for compliance and no substitutions are permitted. |
Packaging instructions
| PICA SICA | SPI no | SPI date | Container NSN |
|---|---|---|---|
| P | F000004XA4 | 04272 | 8115-00-134-3655 |
| S | 00000 | 8145-00-260-9556 |
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- 97
- Dt stdzn dec
- 26-MAR-1999
- NIIN status code
- 0
Cancelled and replaced NIINs
- FSC
- 6110
- Cancelled NIIN
- 6110-01-521-7854
- NIIN status code
- 7
- Effective date
- 22-JUL-2026
- DEMIL code
- D
Request a quote