Catalog item

POWER SUPPLY

6130FSC
01NCB code
067-1655Item number
NIIN 01-067-1655
Request a quote
Unit price
$5,618.47
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00740
PINC
0000740
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
25-OCT-78
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8504900080

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$5,618.471U0NSF9SX-N$0.00F
01-OCT-2026DNJSMSEA0.0000$5,618.471U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$5,618.471U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
6236A28480
HEWLETT-PACKARD COMPANY DBA HP
A593CX4B
HP-6236A28480
HEWLETT-PACKARD COMPANY DBA HP
A595CXB
6236B28480
HEWLETT-PACKARD COMPANY DBA HP
A595CX4B
6236B-12028480
HEWLETT-PACKARD COMPANY DBA HP
A59ECXB
8709-A-20-2.549232
WATCO INC
H59ACXB
MDS 620M85604
KEPCO, INC. DBA KEPCO INC DIV KEPCO DYNATRONIX
A59ECX
MPS 620M85604
KEPCO, INC. DBA KEPCO INC DIV KEPCO DYNATRONIX
A525ZZ4
TP84098095
POWER DESIGNS INC
A595ZZ
TP34098095
POWER DESIGNS INC
A59ACX
86B95006197
MONROE ENGINEERING LLC DBA MONROE PMP
A395ZZ
TP180013850
TECHNIPOWER LLC DBA UNIPOWER
A525ZZ

Characteristics

OVERALL LENGTHINCHES NOMINAL 12.500
OVERALL HEIGHTINCHES NOMINAL 3.500
OVERALL WIDTHINCHES NOMINAL 8.500
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
INPUT PHASESINGLE OPERATING POWER RQMT SINGLE
INPUT VOLTAGE RATINGSINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 104.0 AND AC VOLTS MAXIMUM 127.0
OUTPUT VOLTAGE RATINGFIRST POWER OUTPUT DC VOLTS MINIMUM 0.0 AND DC VOLTS MAXIMUM 20.0
OUTPUT VOLTAGE RATINGSECOND POWER OUTPUT DC VOLTS MINIMUM 0.0 AND DC VOLTS MAXIMUM 6.0
INPUT FREQUENCY RATINGSINGLE OPERATING POWER RQMT HERTZ MINIMUM 47.0 AND HERTZ MAXIMUM 63.0
OPERATING AMBIENT TEMP RANGECELSIUS 0.1 TO 40.0
OUTPUT CONTROL QUANTITY1
OUTPUT CONTROL TYPESECOND POWER OUTPUT VOLTAGE ADJUSTMENT
OUTPUT CONTROL TYPETHIRD POWER OUTPUT VOLTAGE ADJUSTMENT
OUTPUT CONTROL TYPEFIRST POWER OUTPUT VOLTAGE ADJUSTMENT
RECTIFICATION METHODSINGLE PHASE FULL WAVE CENTER TAP
FEATURES PROVIDEDFILTER
OUTPUT CURRENT RATINGSECOND POWER OUTPUT DC AMPERES MINIMUM 1.0 AND DC AMPERES MAXIMUM 2.5
OUTPUT CURRENT RATINGTHIRD POWER OUTPUT DC MILLIAMPERES NOMINAL -500.0
OUTPUT CURRENT RATINGFIRST POWER OUTPUT DC MILLIAMPERES NOMINAL 500.0
OUTPUT CONTROL LOCATIONFIRST POWER OUTPUT TOP PANEL
OUTPUT CONTROL LOCATIONTHIRD POWER OUTPUT TOP PANEL
OUTPUT CONTROL LOCATIONSECOND POWER OUTPUT TOP PANEL
OUTPUT CONNECTION QUANTITY3
OUTPUT CONNECTION TYPESECOND POWER OUTPUT FERRULE
OUTPUT CONNECTION TYPEFIRST POWER OUTPUT FERRULE
OUTPUT CONNECTION TYPETHIRD POWER OUTPUT FERRULE
INPUT CONNECTION TYPESINGLE OPERATING POWER RQMT FERRULE
INPUT CONNECTION QUANTITY2

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-DEC-01YA81YA
YB01YB01-MAR-99YB81YB
YF01YF01-FEB-26YF81YF
YD01YD01-JUN-24YD81YD
YW01YW01-MAR-95YW81YW
ZC01ZC01-APR-91ZC81ZC
ZG01ZG01-JUL-09ZG81ZG
ZH01ZH01-MAR-99ZH81ZH
ZJ01ZJ01-APR-25ZJ81ZJ
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-FEB-07ZU81ZU
ZW01ZW01-DEC-95ZW81ZW
BGX1GE1P01-FEB-05GX01485DGX 48BCX1
FXGGDF1P01-FEB-05ZSXGX01SX5DGX TUFXCX
N9BGDN1P01-FEB-05ZGHGX01GH5DGXHDN9GD

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
SX
PVC
N
ERRC
N

Freight

ACTY CD
CX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
68B0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
A
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
EA
MIL-DTL-17667, neutral wrapping paper
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
10.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2500
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
13873
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
CX
Dt stdzn dec
06-FEB-1982
NIIN status code
0

Request a quote