Catalog item

POWER SUPPLY ASSEMBLY

6130FSC
01NCB code
411-4286Item number
NIIN 01-411-4286
Request a quote
Unit price
$561,194.77
Unit of issue
EA
Source of supply
FLZ
DEMIL code
D

Identification

Item name code
00295
PINC
0000295
Criticality code
Y
II
0
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
24-MAR-95
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
B
Schedule B export code
8529904760
IUID indicator
Y

Management

Effective date
01-OCT-2026
Major organizational entity
DF
Acquisition advice code
V
Source of supply
FLZ
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$561,194.77
Quantity per unit pack
1
Controlled inventory item code
7
Shelf-life code
0
Recoverability code
T
Management control
SF8EW-N
Net price
$66,792.54
USC
L

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
G254084-1V33B150
RAYTHEON COMPANY DBA RAYTHEON CO
A122ZZ
G254084-1V349956
RAYTHEON COMPANY DIV CORP
A592ZZB
G385200-106129
RAYTHEON COMPANY DBA RAYTHEON CO
A322ZZ

Characteristics

OVERALL LENGTHINCHES NOMINAL 17.000
END ITEM IDENTIFICATIONAN/ALQ184 ECM POD
ELECTRICAL POWER SOURCE RELATIONSHIPOPERATING
INPUT VOLTAGE RATINGFOURTH OPERATING POWER RQMT DC VOLTS MINIMUM 4.9 AND DC VOLTS MAXIMUM 5.1
INPUT VOLTAGE RATINGFIRST ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 115.0
INPUT VOLTAGE RATINGSECOND ALTERNATE OPERATING POWER RQMT AC VOLTS NOMINAL 200.0
INPUT VOLTAGE RATINGTHIRD OPERATING POWER RQMT DC VOLTS MINIMUM 14.7 AND DC VOLTS MAXIMUM 15.3
INPUT VOLTAGE RATINGFIFTH OPERATING POWER RQMT DC VOLTS MINIMUM -15.3 AND DC VOLTS MAXIMUM -14.7
INPUT VOLTAGE RATINGSECOND OPERATING POWER RQMT DC VOLTS MINIMUM 27.0 AND DC VOLTS MAXIMUM 29.0
INPUT VOLTAGE RATINGFIRST OPERATING POWER RQMT DC VOLTS MINIMUM 63.0 AND DC VOLTS MAXIMUM 64.0
OUTPUT VOLTAGE RATINGSECOND POWER OUTPUT DC VOLTS MINIMUM -3904.0 AND DC VOLTS MAXIMUM -3896.0
OUTPUT VOLTAGE RATINGTHIRD POWER OUTPUT AC VOLTS MINIMUM 6.0 AND AC VOLTS MAXIMUM 6.6
OUTPUT VOLTAGE RATINGFIRST POWER OUTPUT DC VOLTS MINIMUM 1700.0 AND DC VOLTS MAXIMUM 1900.0
OUTPUT FREQUENCY RATINGTHIRD POWER OUTPUT KILOHERTZ NOMINAL 55.0
POWER UNIT QUANTITY2
CRITICALITY CODE JUSTIFICATIONFEAT
OUTPUT CURRENT RATINGFIRST POWER OUTPUT DC MILLIAMPERES MINIMUM 90.0 AND DC MILLIAMPERES MAXIMUM 120.0
OUTPUT CURRENT RATINGTHIRD POWER OUTPUT AC AMPERES MINIMUM 0.9 AND AC AMPERES MINIMUM 1.3
OUTPUT CURRENT RATINGSECOND POWER OUTPUT DC MILLIAMPERES MINIMUM 1.0 AND DC MILLIAMPERES MAXIMUM 12.0
OUTPUT PHASETHIRD POWER OUTPUT SINGLE
OUTPUT CONNECTION QUANTITY16
OUTPUT CONNECTION QUANTITY8
OUTPUT CONNECTION TYPETHIRD POWER OUTPUT CONNECTOR, RECEPTACLE
OUTPUT CONNECTION TYPEFIRST POWER OUTPUT CONNECTOR, RECEPTACLE
OUTPUT CONNECTION TYPESECOND POWER OUTPUT CONNECTOR, RECEPTACLE
PART NAME ASSIGNED BY CONTROLLING AGENCYPOWER SUPPLY, HIGH VOLTAGE
SPECIAL FEATURESESD ;CAN SUPPLY 8 TWTS, HV RELAY CONTROL/STATUS;RANGE OF LOAD CURRENT FOR HEATER FOR TOTAL TWTS IS 7.2-10.4 ARMS;RANGE OF LOAD CURRENT FOR CATHODE TO GND IS 8.0-96.0MADC FOR 8 TWTS;RANGE OF LOAD CURRENT FOR COLLECTOR TO CATHODE IS 0.72-0.96ADC;OUTPUT FREQUENCY SHOULD BE LESS THAN 55KHZ

MOE rules

MOE rule
FGG4
MOE CD
DF
AMC
0
AMSC
0
NIMSC
F
Date assigned
01-MAR-95
IMC
E
PICA
TG
PICA LOA
22
Auth collab
TU
DSOR
FR

Management phrases

Major organizational entity
DF
USC
L
Phrase code
E
Phrase
REPLACED BY 6130-01-183-3927
Quantity per assembly
0

Service data

Air Force

Fund
SF
Budget
8
MMAC
EW
PVC
N
ERRC
T

Freight

ACTY CD
TK
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
3
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
80Z0
Unpackaged weight
25.0000
Unpackaged width
7.000
Unpackaged length
17.000
Unpackaged height
3.500
Unit of issue
EA
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
GX
Preserve by Method 41 using an approved ESD control program (see 5.2.4.1.1) as follows: Items subject to damage by...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
XX
Cush dun
XX
THK
X
Unit cont
NV
PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
39
ESD sensitive electronic device requirements of MIL-STD-129 apply
Inter cont
00
No requirement.
UCL
B
Unit container provides level B packing protection.
Unit pack weight
34.0000
UP SZ MAXB
15.00000
UP SZ MAXL
25.00000
UP SZ MAXH
14.50000
Unit pack cube
3.1460
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.

Packaging instructions

PICA SICA
P
SPI no
F000009XE3
SPI date
96324
Container NSN
8115-00-550-3558

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
24-MAR-1995
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.