Catalog item
Request a quoteBATTERY,STORAGE
6140FSC
01NCB code
392-0504Item number
NIIN 01-392-0504
- Unit price
- $7,244.63
- Unit of issue
- EA
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00013
- PINC
- 0000013
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 22-JUN-94
- Precious metals indicator
- A
- Hazardous material indicator
- Y
- Hazardous characteristics code
- Z4
- Schedule B export code
- 8507800100
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | EA | 0.0000 | $7,244.63 | 1 | U | K | N | SF9---N | $0.00 | F |
| 01-OCT-2026 | DN | J | SMS | EA | 0.0000 | $7,244.63 | 1 | U | K | 9B----H | $0.00 | N | |
| 01-OCT-2026 | DS | J | SMS | EA | 0.0000 | $7,244.63 | 1 | U | K | N | ------- | $0.00 | I |
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNSC | Hazardous characteristics code | Safety data sheet |
|---|---|---|---|---|---|---|---|---|---|
| RG13-1 | 63017 CONCORDE BATTERY CORPORATION DBA CONCORDE BATTERY CORP | A | 5 | 1 | 5 | ZZ | Z4 | FMVVY | |
| CA54 | 74025 MARATHONNORCO AEROSPACE, INC. DBA MARATHON POWER TECHNOLOGIES COMPANY | A | 5 | 9 | 5 | ZZ | B | ||
| MIL-PRF-8565 | 80205 NATIONAL AEROSPACE STANDARDS COMMITTEE AEROSPACE INDUSTRIES ASSOCIATION OF AMERICA INC NOT FOR RFQ OR SOLICITATION USE | A | 5 | 9 | 5 | ZZ | B | ||
| D8565/13-1 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | 3 | ZZ | |||
| MIL-B-8565 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 3 | ZZ | B | ||
| MIL-PRF-8565/13A | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 3 | ZZ | B | ||
| MIL-PRF-8565/13 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | 3 | ZZ |
Characteristics
| OVERALL LENGTH | MILLIMETERS NOMINAL 318.0 |
|---|---|
| OVERALL HEIGHT | MILLIMETERS NOMINAL 159.5 |
| OVERALL WIDTH | MILLIMETERS NOMINAL 123.8 |
| BATTERY ELECTROLYTE | LEAD ACID |
| AMPERE HOUR CAPACITY | 10.00 |
| VOLTAGE IN VOLTS | 24.0 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | YB | 01-DEC-08 | YB | 81 | YB | ||||||||
| YD01 | YD | 01-FEB-17 | YD | 81 | YD | ||||||||
| ZF01 | ZF | 01-JAN-98 | ZF | 81 | ZF | ||||||||
| ZH01 | ZH | 01-APR-98 | ZH | 81 | ZH | ||||||||
| ZK01 | ZK | 01-AUG-97 | ZK | 81 | ZK | ||||||||
| ZU01 | ZU | 01-AUG-05 | ZU | 81 | ZU | ||||||||
| FXGG | DF | 1 | T | 01-SEP-06 | Z | SX | GX | 01 | SX | 5D | GX TU | FXCX | |
| N9BG | DN | 1 | T | 01-SEP-06 | Z | HD | GX | 01 | GH | 5D | GX | GT KE | N9GD |
Service data
Navy
- COG
- 9B
- SMCC
- H
Air Force
- Fund
- SF
- Budget
- 9
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- CX
- NMFC
- 060680
- NMFC sub
- Z
- Uniform freight class
- 34100
- Less than truckload
- W
- Water commodity code
- 582
- Type of cargo code
- V
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- CD
- NMF description
- BATTERIES OR CELL
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 50Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- A
- Intermediate container qty
- ZZZSpecial requirement: see the specific drawing or instruction provided
- Method of preservation
- HMPackaging and marking for hazardous materials shall comply with applicable requirements for Performance Oriented...
- Clng drying
- ZSpecial requirements - See specific instructions or drawings provided.
- Pres mat
- 00No requirement
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- D3PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 32Type I, shelf life
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 26.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 1.0830
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- PACKAGE IAW U.N. REQUIREM
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 13873
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 22-JUN-1994
- NIIN status code
- 0
Cancelled and replaced NIINs
| FSC | Cancelled NIIN | NIIN status code | Effective date | DEMIL code |
|---|---|---|---|---|
| 6140 | 6140-01-200-4773 | 5 | 02-JUL-2026 | A |
| 6140 | 6140-01-047-0185 | 5 | 02-JUL-2026 | A |
Request a quote