Catalog item

WIRE,ELECTRICAL

6145FSC
00NCB code
312-6106Item number
NIIN 00-312-6106
Request a quote
Unit price
$0.20
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00798
PINC
0000798
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
31-OCT-73
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8548900100

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSFT0.0000$0.20VU0NSF9EH-N$0.00F
01-OCT-2026DMDSMSFT0.0000$0.20VU0Z15B2---$0.00M
01-OCT-2026DNZSMSFT0.0000$0.20VU09B-----$0.00N
01-OCT-2026DSZSMSFT0.0000$0.20VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
A-A-5954458536
FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A41EZZ
THHN/THWN06CG1/14TPJ458536
FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A59EZZB
AA59544THHN/THWN06CG1/14TPJ458536
FEDERAL COMMERCIAL ITEM DESCRIPTION PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A22EZZ
J-C-3081348
FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A593751D
J-C-30THHN/THWN06CG1/14TPJ481348
FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A594KZ4D

Characteristics

TEMP RATINGCELSIUS 90.0
CONDUCTOR FORMSINGLE CONDUCTOR STRANDED
MATERIALCORE CONDUCTOR SINGLE CONDUCTOR COPPER
MATERIALFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC
MATERIALSECOND POSITION JACKET SINGLE CONDUCTOR PLASTIC POLYAMIDE NYLON
COLORFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR YELLOW
CROSS-SECTIONAL SHAPE STYLE
STRAND QUANTITY PER CONDUCTOR19
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.115
VOLTAGE RATINGSINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
ROUND CONDUCTOR SIZESINGLE CONDUCTOR AWG 14
STRAND AWG SIZE PER CONDUCTOR27
SPECIAL FEATURESWIRE DUAL RATED AND MEETS THE PERFORMANCE REQUIREMENTS OF UL TYPES THWN AND THHN

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAAcquisition advice codePICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-AUG-00YA81YA
BGX1GE1G01-APR-06GX01485DGX 48BTX1
DGXTDS1G01-APR-06GX01U55DGX U5KZDTX2
FXGXDF1G01-APR-06ZSXGX01SX5DGX TUFXTX
G860T10001-APR-91C864875 86
G65XHJ1G01-APR-06GX15657D65 GXG65E
MC49DM1G01-APR-06ZPAGX01PA5DGX PAMC13
N9BNDN1G01-APR-06ZGHGX01GH5DGXGTN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
75
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0030
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
01-JAN-1996
NIIN status code
0

Cancelled and replaced NIINs

FSC
6145
Cancelled NIIN
6145-00-935-5142
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.