Catalog item

WIRE,ELECTRICAL

6145FSC
00NCB code
686-4945Item number
NIIN 00-686-4945
Request a quote
Unit price
$0.04
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00798
PINC
0000798
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8548900100
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSFT0.0000$0.04VU0NSF9EH-V$0.00F
01-OCT-2026DSJSMSFT0.0000$0.04VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
XVB730UWHT/GRN3ET41
RSCC WIRE & CABLE LLC DBA MARMON INDUSTRIAL ENERGY & INFRASTRUCTURE - EAST GRANBY
AE85KZ
856650-163B150
RAYTHEON COMPANY DBA RAYTHEON CO
AE8AKZ
856650-1649956
RAYTHEON COMPANY DIV CORP
AE8AKZB
856650-1654X10
RAYTHEON COMPANY
AE85ZZ
MIL-DTL-16878/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-W-16878/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594KZ1B
M16878/1BFB9581349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A224KZ4
7055-1392194
BELDEN, INC.
A595SBB
XVB730UWHT/GRN90484
RSCC WIRE & CABLE LLC
RE8EKZ

Characteristics

MATERIALFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE (PVC)
STRAND QUANTITY PER CONDUCTOR7
CONDUCTOR FORMSINGLE CONDUCTOR STRANDED
ROUND CONDUCTOR SIZESINGLE CONDUCTOR AWG 22
STRAND AWG SIZE PER CONDUCTOR30
VOLTAGE RATINGSINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
COLORFIRST POSITION COVER SINGLE CONDUCTOR WHITE
CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS 105.0
SURFACE TREATMENTCORE CONDUCTOR SINGLE CONDUCTOR TIN
MATERIALCORE CONDUCTOR SINGLE CONDUCTOR COPPER ALLOY 101 OR COPPER ALLOY 102
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR SINGLE CONDUCTOR ASSN STD ALL MATERIAL RESPONSES AST- B33
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR SINGLE CONDUCTOR ASSN STD SINGLE TREATMENT RESPONSE AST- B33-63
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.049
TRACER COLORFIRST TRACER SINGLE CONDUCTOR GREEN

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
1
AMSC
G
Date assigned
01-NOV-05
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Management phrases

Major organizational entity
DF
USC
F
Phrase code
R
Phrase
REFER TO X008152749SB
Quantity per assembly
0
Technical document
X008152749SB

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
GX
Dt stdzn dec
01-JUN-2021
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
61456145-01-046-2148502-JUL-2026A
61456145-01-332-3408522-JUL-2026A
61456145-00-850-9454702-JUL-2026A

Request a quote