Catalog item

WIRE,ELECTRICAL

6145FSC
00NCB code
686-4948Item number
NIIN 00-686-4948
Request a quote
Unit price
$0.04
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00798
PINC
0000798
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8548900100

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSFT0.0000$0.04VU0NSF9EH-V$0.00F
01-OCT-2026DNJSMSFT0.0000$0.04VU09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$0.04VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCRNJC
856650-123B150
RAYTHEON COMPANY DBA RAYTHEON CO
AE8AKZ
XVB730UWHT/BRN3ET41
RSCC WIRE & CABLE LLC DBA MARMON INDUSTRIAL ENERGY & INFRASTRUCTURE - EAST GRANBY
AE85KZ
856650-1249956
RAYTHEON COMPANY DIV CORP
AE8AKZB
856650-1254X10
RAYTHEON COMPANY
AE85ZZ
MIL-W-16878/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594KZ1B
M16878/1BFB9181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A224KZ4
MIL-DTL-16878/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
7055-1692194
BELDEN, INC.
A595SBB
XVB730UWHT/BRN90484
RSCC WIRE & CABLE LLC
RE8EKZ

Characteristics

MATERIALCORE CONDUCTOR SINGLE CONDUCTOR COPPER ALLOY 101 OR COPPER ALLOY 102
CROSS-SECTIONAL SHAPE STYLE
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR SINGLE CONDUCTOR ASSN STD ALL MATERIAL RESPONSES AST- B33
TRACER COLORFIRST TRACER SINGLE CONDUCTOR BROWN
COLORFIRST POSITION COVER SINGLE CONDUCTOR WHITE
VOLTAGE RATINGSINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
SURFACE TREATMENTCORE CONDUCTOR SINGLE CONDUCTOR TIN
MATERIALFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE (PVC)
CONDUCTOR FORMSINGLE CONDUCTOR STRANDED
ROUND CONDUCTOR SIZESINGLE CONDUCTOR AWG 22
STRAND AWG SIZE PER CONDUCTOR30
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR SINGLE CONDUCTOR ASSN STD SINGLE TREATMENT RESPONSE AST- B33-63
TEMP RATINGCELSIUS 105.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.049
STRAND QUANTITY PER CONDUCTOR7

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-APR-91ZC81ZC
FXGXDF1G01-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN1G01-NOV-05ZGHGX01GH5DGXHDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
XX
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
7.8000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
GX
Dt stdzn dec
01-JUN-2021
NIIN status code
0

Cancelled and replaced NIINs

FSCCancelled NIINNIIN status codeEffective dateDEMIL code
61456145-01-046-2146502-JUL-2026A
61456145-01-331-7794522-JUL-2026A
61456145-00-850-9453702-JUL-2026A

Request a quote