Catalog item

CABLE,SPECIAL PURPOSE,ELECTRICAL

6145FSC
00NCB code
763-2901Item number
NIIN 00-763-2901
Request a quote
Unit price
$1.01
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16488
PINC
0016488
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
14-APR-72
Precious metals indicator
S
Hazardous material indicator
N
Schedule B export code
8548900100

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSFT0.0000$1.01VU0NSF9EH-V$0.00F
01-OCT-2026DNJSMSFT0.0000$1.01VU09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$1.01VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
EC20U9-0S81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594ZZB
MIL-DTL-55021/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
E20C9-0S81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594ZZB
E20C0-9S81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MIL-C-55021/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A594KZ1B
2815/292194
BELDEN, INC.
A514ZZ

Characteristics

MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -65.0 AND CELSIUS 200.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.142
PRECIOUS MATERIALSILVER
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS SILVER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B298
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR BLACK
CONDUCTOR FORMALL CONDUCTORS STRANDED
CONDUCTOR QUANTITY2
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYTETRAFLUOROETHYLENE
MATERIALFIRST POSITION SHIELD BRAID METALLIC CABLE COPPER
MATERIALSECOND POSITION COATING CABLE SILVER
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 20
STRAND AWG SIZE PER CONDUCTOR32
CONDUCTOR ARRANGEMENT AND QUANTITYTWISTED PAIR 1
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR WHITE
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS FED SPEC SINGLE MATERIAL RESPONSE QQ-W-343,SOFT
PRECIOUS MATERIAL AND LOCATIONSILVER SURFACE ALL CONDUCTORS AND SILVER SURFACE SHIELD BRAID
STRAND QUANTITY PER CONDUCTOR19

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YA01YA01-SEP-00YA81YA
FXGXDF0001-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN0001-NOV-05ZGHGX01GH5DGXHXN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
V
ERRC
N

Freight

ACTY CD
KZ
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
27A0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
X
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
KZ
Dt stdzn dec
14-FEB-1972
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.