Catalog item

CABLE,SPECIAL PURPOSE,ELECTRICAL

6145FSC
01NCB code
133-1216Item number
NIIN 01-133-1216
Request a quote
Unit price
$123.07
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16488
PINC
0016488
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
09-JUN-82
Precious metals indicator
A
Hazardous material indicator
N
Schedule B export code
8548900100
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSFT0.0000$123.07VU0NSF9EH-N$0.00F
01-OCT-2026DNJSMSFT0.0000$123.07VU09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$123.07VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
5049/255F262
GENERAL WIRE PRODUCTS, INC. DBA GENERAL WIRE PRODUCTS INC
A52EZZ
M464662132
MANHATTAN ELECTRIC CABLE CORP
H59EKZB
MW1280163364
MERCURY WIRE PRODUCTS, INC. DBA MERCURY WIRE PRODUCTS INC
A324ZZ
5199/2592194
BELDEN, INC.
A594KZB
5199/25C92194
BELDEN, INC.
A524KZ
2378497324
CHAMPLAIN CABLE LEEDS CORPORATION
A52EKZ
AA-14430FDY2
SABNIS, DR SUMAN T DBA K S S ASSOCIATES
H594ZZB
1522250LWG7
COMMUNICATION CABLE INC SAXTON WIRE AND CABLE DIV
A52EZZ
2127-07140-0114590
VERIDIAN ENGINEERING INC
H595KZB

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS 80.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.380
CONDUCTOR QUANTITY25
ACCESSORY WIRE TYPE AND QUANTITYDRAIN 1
COLOR CODING DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 5199 TO 25-92194
STRAND QUANTITY PER CONDUCTOR7
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 22
STRAND AWG SIZE PER CONDUCTOR30
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 25
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0
COLORFIRST POSITION JACKET CABLE GRAY/GREY
MATERIALFIRST POSITION SHIELD FOIL CABLE PLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER)
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC)
MATERIALSECOND POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC)
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
SURFACE TREATMENTSIXTH POSITION SHIELD FOIL CABLE ALUMINUM
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS TIN

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
BGX1GE1Z01-NOV-05GX01485DGX 48BTX1
FXGXDF1Z01-NOV-05ZSXGX01SX5DGX TUFXTX
N9BNDN1Z01-NOV-05ZGHGX01GH5DGXN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KZ
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
93279

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
KZ
Dt stdzn dec
10-JUN-1982
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.