Catalog item

CABLE,SPECIAL PURPOSE,ELECTRICAL

6145FSC
01NCB code
234-2916Item number
NIIN 01-234-2916
Request a quote
Unit price
$4.73
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16488
PINC
0016488
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-JUN-86
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8548900100
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSFT0.0000$4.73VU0NSF9EH-N$0.00F
01-OCT-2026DMJSMSFT0.0000$4.73VU0Z15B2--1$0.00M
01-OCT-2026DNZSMSFT0.0000$4.73VU09B-----$0.00N
01-OCT-2026DSZSMSFT0.0000$4.73VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
835592W733
BELDEN WIRE AND CABLE CO WIRE AND CABLE OFFICE
A594ZZB
1984R0T429
AEROSPACE WIRE & CABLE, INC.
A525ZZ
8355916428
BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
A32475

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -70.0 AND CELSIUS 200.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.211
CONDUCTOR QUANTITY9
TRACER COLORSINGLE TRACER NINTH CONDUCTOR BLACK
TRACER COLORSINGLE TRACER EIGHTH CONDUCTOR BLACK
TRACER COLORSINGLE TRACER SEVENTH CONDUCTOR BLACK
STRAND QUANTITY PER CONDUCTOR7
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 22
STRAND AWG SIZE PER CONDUCTOR30
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 9
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0
COLORFIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR BLUE
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE
COLORFIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR ORANGE
COLORFIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR GREEN
COLORFIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR RED
COLORFIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR GREEN
COLORFOURTH POSITION JACKET CABLE RED
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR WHITE
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALFOURTH POSITION JACKET CABLE PLASTIC FLUORINATED ETHYLENE PROPYLENE
MATERIALTHIRD POSITION SHIELD BRAID METALLIC CABLE COPPER
MATERIALSECOND POSITION SHIELD FOIL CABLE ALUMINUM AND PLASTIC POLYESTER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC FLUORINATED ETHYLENE PROPYLENE
SURFACE TREATMENTTHIRD POSITION SHIELD BRAID METALLIC CABLE TIN
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS TIN

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
FXGXDF3Z01-NOV-05ZSXGX01SX5DGX TUFXTX
MC49DM3Z01-NOV-09ZPAGX01PA5DGX PA
N9BNDN3Z01-DEC-13ZGHGX01GH5DGXGG

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2
PCC
1

Freight

ACTY CD
92
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
27AZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0070
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
13-JUN-1986
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.