Catalog item
Request a quoteCABLE,POWER,ELECTRICAL
6145FSC
01NCB code
236-7158Item number
NIIN 01-236-7158
- Unit price
- $27.58
- Unit of issue
- FT
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00232
- PINC
- 0000232
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 22-JUL-86
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8544606000
Management
- Effective date
- 01-OCT-2026
- Major organizational entity
- DS
- Acquisition advice code
- J
- Source of supply
- SMS
- Unit of issue
- FT
- Unit of measure quantity
- 0.0000
- Unit price
- $27.58
- Quantity per unit pack
- V
- Controlled inventory item code
- U
- Shelf-life code
- 0
- Recoverability code
- N
- Management control
- -------
- Net price
- $0.00
- USC
- I
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNSC | SADC |
|---|---|---|---|---|---|---|---|---|
| GC18F7-16J | 26512 NORTHROP GRUMMAN SYSTEMS CORPORATION | A | 5 | 9 | 4 | KZ | B | |
| GC875RW7-16J | 26512 NORTHROP GRUMMAN SYSTEMS CORPORATION | A | 3 | 2 | A | ZZ | ||
| GC875RW7-16J | 3ET41 RSCC WIRE & CABLE LLC DBA MARMON INDUSTRIAL ENERGY & INFRASTRUCTURE - EAST GRANBY | A | C | 1 | 5 | ZZ | 9F | |
| GC875RW7-16J | 71124 PRYSMIAN CABLES AND SYSTEMS USA, LLC DIV MANUFACTURING PLANT | A | 5 | 2 | 5 | ZZ | ||
| MIL-C-27500 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | KZ | B | |
| M27500-16ML7U08 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | KZ | B | |
| GC875RW7-16J | 90484 RSCC WIRE & CABLE LLC | R | 5 | 9 | 5 | ZZ | B | |
| GC875RW7-16J | 06090 TE CONNECTIVITY CORPORATION DBA RAYCHEM PRODUCT DIVISION | A | 5 | 2 | 5 | ZZ | ||
| GC875RW7-16J | 12703 JUDD WIRE INC. DBA JUDD WIRE INC | A | 5 | 2 | 5 | ZZ | ||
| GC875RW7-16J | 12515 NEXANS AEROSPACE USA LLC | A | 5 | 2 | 5 | ZZ |
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TEMP RATING | CELSIUS 150.0 |
| CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.261 |
| CONDUCTOR QUANTITY | 7 |
| STRAND QUANTITY PER CONDUCTOR | 19 |
| CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 16 |
| STRAND AWG SIZE PER CONDUCTOR | 29 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 7 |
| VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0 |
| SPECIAL FEATURES | OPTIONAL IDENTIFICATION METHOD 1 APPLIES |
| COLOR | FIRST POSITION JACKET CABLE WHITE |
| MATERIAL | SECOND POSITION JACKET ALL CONDUCTORS PLASTIC POLYVINYLIDENE FLUORIDE |
| MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER ALLOY 101 OR COPPER ALLOY 102 |
| MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYALKENE |
| MATERIAL | FIRST POSITION JACKET CABLE PLASTIC POLYVINYLIDENE FLUORIDE |
| MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B33 |
| SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B33-63 |
| DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY OPTIONAL IDENTIFICATION METHOD |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|---|---|
| YA01 | YA | 01-JUL-01 | YA | 81 | YA | ||
| DGX1 | DS | 1 | C | 01-JUN-13 | GX | 01 | GX |
Freight
- ACTY CD
- KH
- NMFC
- 030310
- NMFC sub
- Z
- Uniform freight class
- 15080
- Less than truckload
- W
- Water commodity code
- 743
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- CABLE OR WIRE
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60ZZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- PRESERVATION AND PACKAGING
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 13873
- SPI date
- 85046
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 22-JUL-1986
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.