Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
255-5070Item number
NIIN 01-255-5070
Request a quote
Unit price
$5.01
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
21-MAY-87
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSFT0.0000$5.01VU0NSF9EH-N$0.00F
01-OCT-2026DSJSMSFT0.0000$5.01VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
6860-48241V680
J A M INDUSTRIES
A52EZZ
M974608056994
INSCON CABLE CORP
A52EZZ
5470B16085F262
GENERAL WIRE PRODUCTS, INC. DBA GENERAL WIRE PRODUCTS INC
A52EZZ
5620B1608E92194
BELDEN, INC.
A325ZZ
5620B160892194
BELDEN, INC.
A52EZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -40.0 AND CELSIUS 90.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.747
CONDUCTOR QUANTITY16
ACCESSORY WIRE TYPE AND QUANTITYDRAIN 8
COLOR CODING DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 5620B1608-92194
STRAND QUANTITY PER CONDUCTOR7
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 16
STRAND AWG SIZE PER CONDUCTOR24
CONDUCTOR ARRANGEMENT AND QUANTITYTWISTED PAIR 8
CONDUCTOR SEQUENCE WITHIN GROUPSFIRST GROUP FIRST CONDUCTOR AND SECOND CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSSECOND GROUP THIRD CONDUCTOR AND FOURTH CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSFIFTH GROUP NINTH CONDUCTOR AND TENTH CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSFOURTH GROUP SEVENTH CONDUCTOR AND EIGHTH CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSTHIRD GROUP FIFTH CONDUCTOR AND SIXTH CONDUCTOR
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0
SPECIAL FEATURESSIXTH GROUPING ARRANGEMENT ELEVENTH AND TWELFTH CONDUCTOR THROUGH EIGHTH GROUPING ARRANGEMENT FIFTEENTH AND SIXTEENTH CONDUCTOR. EACH GROUPING ARRANGEMENT CONTAINS ONE BLACK CONDUCTOR,ONE WHITE CONDUCTOR AND A DRAIN WIRE
COLORFIRST POSITION JACKET CABLE BLACK
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC)

MOE rules

MOE rule
FXGX
MOE CD
DF
AMC
1
AMSC
G
Date assigned
01-NOV-05
IMC
Z
IMCA
SX
PICA
GX
PICA LOA
01
SICA
SX
SICA LOA
5D
Auth collab
GX TU
Fmr MOE rl
FXTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KH
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
80Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
0.4000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
21-MAY-1987
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.