Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
268-6905Item number
NIIN 01-268-6905
Request a quote
Unit price
$1.46
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
04-DEC-87
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSFT0.0000$1.46VU09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$1.46VU0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
UL6281345
UNDERWRITERS LABORATORIES INC
A31EZZ
UL62SJTO3BCK3/16PVCPVC81345
UNDERWRITERS LABORATORIES INC
A32EZZ
J-C-580SJTO3CK3/16TTJ81348
FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A59EKZB
J-C-58081348
FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES ADMINISTRATION WASHINGTON DC
A59EKZB
ES-06583-063-00007909
SOUTHWIRE COMPANY DOUGLAS PLANT
A51EKZ
16-3 SJT007909
SOUTHWIRE COMPANY DOUGLAS PLANT
AC16ZZAC

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS 60.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.325
CONDUCTOR QUANTITY3
STRAND QUANTITY PER CONDUCTOR26
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 16
STRAND AWG SIZE PER CONDUCTOR30
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 3
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0
SPECIAL FEATURESOPTIONAL TRACER THIRD CONDUCTOR YELLOW
MATERIALFIRST POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC)
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC)

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
G
Date assigned
01-NOV-05
IMC
Z
IMCA
GH
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
HD
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KZ
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
10
Physical protection
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
00
No requirement
THK
0
Not applicable
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
25.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2840
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
04-DEC-1987
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.