Catalog item

CABLE,SPECIAL PURPOSE,ELECTRICAL

6145FSC
01NCB code
340-1305Item number
NIIN 01-340-1305
Request a quote
Unit price
$2.01
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16488
PINC
0016488
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
10-JUN-91
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8548900100
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSFT0.0000$2.011U0NSF9EH-N$0.00F
01-OCT-2026DMJSMSFT0.0000$2.01ZU0Z12B2--1$0.00M
01-OCT-2026DNZSMSFT0.0000$2.01ZU09B-----$0.00N
01-OCT-2026DSZSMSFT0.0000$2.01ZU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
44893N861
JANOR WIRE & CABLE CORP
A52EKZ
GW80135F262
GENERAL WIRE PRODUCTS, INC. DBA GENERAL WIRE PRODUCTS INC
A325ZZ
C092581774
GENERAL CABLE CORPORATION DIV CORPORATE
A524ZZ
AA-15780FDY2
SABNIS, DR SUMAN T DBA K S S ASSOCIATES
H595ZZB
816316428
BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
A52EKZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS 60.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.367
CONDUCTOR QUANTITY6
ACCESSORY WIRE TYPE AND QUANTITYDRAIN 3
STRAND QUANTITY PER CONDUCTOR7
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 24
STRAND AWG SIZE PER CONDUCTOR32
CONDUCTOR ARRANGEMENT AND QUANTITYTWISTED PAIR 3
GROUP QUANTITY3
CONDUCTOR GROUPING ARRANGEMENT TYPE AND QUANTITYALL GROUPS TWISTED PAIR 3
CONDUCTOR SEQUENCE WITHIN GROUPSSECOND GROUP THIRD CONDUCTOR AND FOURTH CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSFIRST GROUP FIRST CONDUCTOR AND SECOND CONDUCTOR
CONDUCTOR SEQUENCE WITHIN GROUPSTHIRD GROUP FIFTH CONDUCTOR AND SIXTH CONDUCTOR
COLORFIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR WHITE
COLORFIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR GREEN
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR RED
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR BLACK
COLORFOURTH POSITION JACKET CABLE CHROME
MATERIALFOURTH POSITION SHIELD BRAID METALLIC CABLE COPPER
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC, POLYETHYLENE (PP)
MATERIALTHIRD POSITION SHIELD FOIL CABLE PLASTIC POLYESTER AND ALUMINUM
MATERIALSECOND POSITION SHIELD FOIL ALL GROUPS PLASTIC POLYESTER AND ALUMINUM
MATERIALFIFTH POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC)
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS TIN
SURFACE TREATMENTTHIRD POSITION SHIELD BRAID METALLIC CABLE TIN
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONTHIRD POSITION SHIELD BRAID METALLIC CABLE MFR REF SINGLE TREATMENT RESPONSE 8163,CAGE16428
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS MFR REF SINGLE TREATMENT RESPONSE 8163,CAGE16428

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
FXGXDF1Z01-NOV-05ZSXGX01SX5DGX TUFXTX
MC49DM1Z01-DEC-13ZPAGX01PA5DGX PA
N9BNDN1Z01-DEC-13ZGHGX01GH5DGXGT GG

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
2
MEC
B2
PCC
1

Freight

ACTY CD
KH
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
SPECIAL QUP CODE ZZZ = 10

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
10-JUN-1991
NIIN status code
0

Request a quote