Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
357-3963Item number
NIIN 01-357-3963
Request a quote
Unit price
$1.14
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
22-APR-92
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFZSMSFT0.0000$1.14UU0NSF9EH-N$0.00F
01-OCT-2026DMZSMSFT0.0000$1.14UU0Z12B2--1$0.00M
01-OCT-2026DNZSMSFT0.0000$1.14UU09B-----$0.00N
01-OCT-2026DSZSMSFT0.0000$1.14UU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSCSADC
4336-1382879
YORK TECHNICAL INSTITUTE LLC DBA YTI CAREER INSTITUTE-MECHANICSBURG
HC11ZZAC
W433682879
YORK TECHNICAL INSTITUTE LLC DBA YTI CAREER INSTITUTE-MECHANICSBURG
H594KZB
W433607909
SOUTHWIRE COMPANY DOUGLAS PLANT
A324ZZ
02765-1507759
COUNTY OF MANATEE
A59EKZ
0276507759
COUNTY OF MANATEE
A59EKZB
W82-0003-31614304
L3HARRIS TECHNOLOGIES, INC. DBA HARRIS CORP DIV HARRIS DEFENSE COMMUNICATIONS
A722ZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -40.0 AND CELSIUS 90.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.390
CONDUCTOR QUANTITY3
STRAND QUANTITY PER CONDUCTOR26
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 16
STRAND AWG SIZE PER CONDUCTOR30
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 3
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
SPECIAL FEATURESJACKET MATERIAL IS CAROLPRENE A PROPRIETARY COMPOUND OF CHLORINATED POLYETHYLENE AND CORD IS UL TYPES SOW-A/SO
COLORTHIRD POSITION JACKET CABLE BLACK
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR GREEN
MATERIALSECOND POSITION SEPARATOR CABLE PAPER
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS RUBBER ETHYLENE-PROPYLENE-DIENE CLASS EPDM
MATERIALTHIRD POSITION JACKET CABLE RUBBER SYNTHETIC
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B174

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
ZC01ZC01-JUL-94ZC81ZC
ZI01ZI01-NOV-20ZI81ZI
FXGXDF1C01-NOV-05ZSXGX01SX5DGX TUFXTX
MC49DM1C01-NOV-05ZPAGX01PA5DGX PAMC13
N9BNDN1C01-NOV-05ZGHGX01GH5DGXHX GT KE HDN9ND

Service data

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
2
MEC
B2
PCC
1

Freight

ACTY CD
KZ
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
22-APR-1992
NIIN status code
0

Cancelled and replaced NIINs

FSC
6145
Cancelled NIIN
6145-01-359-4147
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote