Catalog item
Request a quoteCABLE,SPECIAL PURPOSE,ELECTRICAL
6145FSC
01NCB code
357-3970Item number
NIIN 01-357-3970
- Unit price
- $0.43
- Unit of issue
- FT
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 16488
- PINC
- 0016488
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 22-APR-92
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8548900100
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | FT | 0.0000 | $0.43 | V | U | 0 | N | SF9EH-N | $0.00 | F |
| 01-OCT-2026 | DS | J | SMS | FT | 0.0000 | $0.43 | V | U | 0 | N | ------- | $0.00 | I |
Part numbers
- Part number
- C0782
- CAGE
- 81774GENERAL CABLE CORPORATION DIV CORPORATE
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- KZ
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TEMP RATING | CELSIUS -20.0 AND CELSIUS 80.0 |
| CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.250 |
| CONDUCTOR QUANTITY | 4 |
| ACCESSORY WIRE TYPE AND QUANTITY | DRAIN 1 |
| STRAND QUANTITY PER CONDUCTOR | 10 |
| CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 20 |
| STRAND AWG SIZE PER CONDUCTOR | 30 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 4 |
| VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0 |
| COLOR | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED |
| COLOR | FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR GREEN |
| COLOR | THIRD POSITION JACKET CABLE CHROME |
| COLOR | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK |
| COLOR | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE |
| MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC) |
| MATERIAL | THIRD POSITION JACKET CABLE PLASTIC POLYVINYL CHLORIDE (PVC) |
| MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| MATERIAL | SECOND POSITION SHIELD FOIL CABLE ALUMINUM AND PLASTIC POLYESTER |
| MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B33 |
| SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B33 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WP01 | WP | 01-SEP-07 | WP | 81 | WP | |||||||
| FXGX | DF | 0 | 0 | 01-NOV-05 | Z | SX | GX | 01 | SX | 5D | GX TU | FXTX |
Service data
Air Force
- Fund
- SF
- Budget
- 9
- MMAC
- EH
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- KZ
- NMFC
- 030310
- NMFC sub
- Z
- Uniform freight class
- 15080
- Less than truckload
- W
- Water commodity code
- 743
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- CABLE OR WIRE
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 85Z0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- XXX
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- C3/4 inch thick
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- ZZSpecial requirements
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- Lvl A
- QPacking shall be accomplished in accordance with table C.II for the packing level specified.
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- PRESERVATION AND PACKAGING
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 14933
- SPI date
- 88090
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 22-APR-1992
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.