Catalog item

CABLE,SPECIAL PURPOSE,ELECTRICAL

6145FSC
01NCB code
384-3490Item number
NIIN 01-384-3490
Request a quote
Unit price
$14.97
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16488
PINC
0016488
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-DEC-93
Precious metals indicator
S
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8548900100
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSFT0.0000$14.97ZU0AQ2200X-$0.00A
01-OCT-2026DFJSMSFT0.0000$14.971U0NSF9EH-N$0.00F
01-OCT-2026DSJSMSFT0.0000$14.97ZU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
02331-1763 935683N861
JANOR WIRE & CABLE CORP
A325ZZ
2817-692194
BELDEN, INC.
A52EZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS 200.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.210
CONDUCTOR QUANTITY6
STRAND QUANTITY PER CONDUCTOR19
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 20
STRAND AWG SIZE PER CONDUCTOR32
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 6
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
COLORFIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR BLUE
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR YELLOW
COLORFIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR GREEN
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR WHITE
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC TETRAFLUOROETHYLENE
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALSECOND POSITION SHIELD BRAID METALLIC CABLE COPPER
MATERIALTHIRD POSITION JACKET CABLE PLASTIC FLUORINATED ETHYLENE PROPYLENE AND GLASS FIBER
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B298
MATERIAL DOCUMENT AND CLASSIFICATIONSECOND POSITION SHIELD BRAID METALLIC CABLE ASSN STD SINGLE MATERIAL RESPONSE AST- B298
PRECIOUS MATERIAL AND LOCATIONSILVER SURFACE ALL CONDUCTORS
PRECIOUS MATERIALSILVER
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS SILVER
SURFACE TREATMENTSECOND POSITION SHIELD BRAID METALLIC CABLE SILVER
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONSECOND POSITION SHIELD BRAID METALLIC CABLE ASSN STD SINGLE TREATMENT RESPONSE AST- B298
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B298

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
A918DA1G01-DEC-06ZCTGX01CD5DCD GXCT
FXGXDF1G01-NOV-05ZSXGX01SX5DGX TUFXTX

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Freight

ACTY CD
KH
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
00
No requirement.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
6
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0020
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
SPECIAL QUP CODE ZZZ / 10

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
88090

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
14-DEC-1993
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.