Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
412-7517Item number
NIIN 01-412-7517
Request a quote
Unit price
$10.01
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
27-APR-95
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DAJSMSFT0.0000$10.01VU0ZQ2200X-$0.00A
01-OCT-2026DFJSMSFT0.0000$10.01VU0NSF9EH-N$0.00F
01-OCT-2026DMJSMSFT0.0000$10.01VU0Z15B2---$0.00M
01-OCT-2026DNJSMSFT0.0000$10.01VU09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$10.01VU0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
TYW600V5CONDNO6-259STRNDCOND79277
TELEDYNE WESTERN WIRE AND CABLE TELEDYNE INDUSTRIES INC
H395ZZ
C10658-481755
LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A721ZZ
8162581774
GENERAL CABLE CORPORATION DIV CORPORATE
A324ZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -40.0 AND CELSIUS 90.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 1.210
CONDUCTOR QUANTITY5
STRAND QUANTITY PER CONDUCTOR259
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 6
STRAND AWG SIZE PER CONDUCTOR30
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 5
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
SPECIAL FEATURESOUTER JACKET COMPOUND IS SUPER VU-TRON II.II
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR GREEN
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE
COLORFIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR ORANGE
COLORSECOND POSITION JACKET CABLE BLACK
COLORFIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR RED
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALSECOND POSITION JACKET CABLE RUBBER SYNTHETIC
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS RUBBER ETHYLENE-PROPYLENE-DIENE CLASS EPDM
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B172

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
A918DA3Z01-NOV-05ZCDGX01CD5DCD GXBDA196
FXGXDF3Z01-NOV-05ZSXGX01SX5DGX TUFXTX
MC49DM3Z01-NOV-05ZPAGX01PA5DGX PAMC13
N9BNDN3Z01-NOV-05ZGHGX01GH5DGXHD HXN9ND

Service data

Army

Matcat 1
Q
Matcat 2
2
Matcat 3
2
Matcat 4 5
00
ARC
X

Navy

COG
9B

Air Force

Fund
SF
Budget
9
MMAC
EH
PVC
N
ERRC
N

Marine Corps

SAC
1
CEC
5
MEC
B2

Freight

ACTY CD
KH
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
85Z0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
XXX
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
1.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0110
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
96248

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
27-APR-1995
NIIN status code
0

Cancelled and replaced NIINs

FSC
6145
Cancelled NIIN
6145-01-112-6713
NIIN status code
7
Effective date
22-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.