Catalog item
Request a quoteCABLE,POWER,ELECTRICAL
6145FSC
01NCB code
432-9220Item number
NIIN 01-432-9220
- Unit price
- $4.61
- Unit of issue
- FT
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 00232
- PINC
- 0000232
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 18-JUN-96
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8544606000
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | X | SMS | FT | 0.0000 | $4.61 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | X | SMS | FT | 0.0000 | $4.61 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TEMP RATING | CELSIUS -20.0 AND CELSIUS 60.0 |
| CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.480 |
| CONDUCTOR QUANTITY | 10 |
| STRAND QUANTITY PER CONDUCTOR | 41 |
| CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 18 |
| STRAND AWG SIZE PER CONDUCTOR | 34 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 10 |
| VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0 |
| COLOR | FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR ORANGE |
| COLOR | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK |
| COLOR | FIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR GRAY/GREY |
| COLOR | FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR YELLOW |
| COLOR | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED |
| COLOR | FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR BLUE |
| COLOR | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE |
| COLOR | FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR BROWN |
| COLOR | FIFTH POSITION JACKET CABLE BLACK |
| COLOR | FIRST POSITION PRIMARY INSULATION TENTH CONDUCTOR VIOLET |
| COLOR | FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR GREEN |
| MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS RUBBER |
| MATERIAL | FIFTH POSITION JACKET CABLE RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM |
| MATERIAL | FOURTH POSITION WRAP CABLE PLASTIC POLYESTER |
| MATERIAL | THIRD POSITION SHIELD BRAID METALLIC CABLE COPPER |
| MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| MATERIAL | SECOND POSITION WRAP CABLE PLASTIC POLYESTER |
| MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B33 |
| SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| SURFACE TREATMENT | THIRD POSITION SHIELD BRAID METALLIC CABLE TIN |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B33 |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | Date assigned | IMC | IMCA | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| YB01 | YB | 01-JUL-24 | YB | 81 | YB | ||||||||
| ZW01 | ZW | 01-DEC-05 | ZW | 81 | ZW | ||||||||
| N9BN | DN | 1 | G | 01-NOV-05 | Z | GH | GX | 01 | GH | 5D | GX | KE | N9ND |
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- KZ
- NMFC
- 030310
- NMFC sub
- Z
- Uniform freight class
- 15080
- Less than truckload
- W
- Water commodity code
- 743
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- CABLE OR WIRE
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- ZZCZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 14.000
- Unpackaged length
- 14.000
- Unpackaged height
- 3.500
- TOS
- B
- Intermediate container qty
- ZZZSpecial requirement: see the specific drawing or instruction provided
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- ZSpecial requirements - See specific instructions or drawings provided.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- UCL
- BUnit container provides level B packing protection.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- UItems or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 14.80000
- UP SZ MAXL
- 14.80000
- UP SZ MAXH
- 4.70000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- PRESERVATION AND PACKAGING
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 18-JUN-1996
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.