Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
432-9220Item number
NIIN 01-432-9220
Request a quote
Unit price
$4.61
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
18-JUN-96
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNXSMSFT0.0000$4.611U09B-----$0.00N
01-OCT-2026DSXSMSFT0.0000$4.611U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
3070AS714-130003
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
A32AZZ
C121081774
GENERAL CABLE CORPORATION DIV CORPORATE
A524ZZ

Characteristics

CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -20.0 AND CELSIUS 60.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.480
CONDUCTOR QUANTITY10
STRAND QUANTITY PER CONDUCTOR41
CONDUCTOR FORMALL CONDUCTORS STRANDED
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 18
STRAND AWG SIZE PER CONDUCTOR34
CONDUCTOR ARRANGEMENT AND QUANTITYSINGLES 10
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0
COLORFIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR ORANGE
COLORFIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK
COLORFIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR GRAY/GREY
COLORFIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR YELLOW
COLORFIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED
COLORFIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR BLUE
COLORFIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE
COLORFIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR BROWN
COLORFIFTH POSITION JACKET CABLE BLACK
COLORFIRST POSITION PRIMARY INSULATION TENTH CONDUCTOR VIOLET
COLORFIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR GREEN
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS RUBBER
MATERIALFIFTH POSITION JACKET CABLE RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM
MATERIALFOURTH POSITION WRAP CABLE PLASTIC POLYESTER
MATERIALTHIRD POSITION SHIELD BRAID METALLIC CABLE COPPER
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALSECOND POSITION WRAP CABLE PLASTIC POLYESTER
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B33
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS TIN
SURFACE TREATMENTTHIRD POSITION SHIELD BRAID METALLIC CABLE TIN
SURFACE TREATMENT DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE TREATMENT RESPONSE AST- B33

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabFmr MOE rl
YB01YB01-JUL-24YB81YB
ZW01ZW01-DEC-05ZW81ZW
N9BNDN1G01-NOV-05ZGHGX01GH5DGXKEN9ND

Service data

Navy

COG
9B

Freight

ACTY CD
KZ
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
ZZCZ
Unpackaged weight
0.0000
Unpackaged width
14.000
Unpackaged length
14.000
Unpackaged height
3.500
TOS
B
Intermediate container qty
ZZZ
Special requirement: see the specific drawing or instruction provided
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
UCL
B
Unit container provides level B packing protection.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.0000
UP SZ MAXB
14.80000
UP SZ MAXL
14.80000
UP SZ MAXH
4.70000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PRESERVATION AND PACKAGING

Packaging instructions

PICA SICA
P
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
18-JUN-1996
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.