Catalog item
Request a quoteCABLE,SPECIAL PURPOSE,ELECTRICAL
6145FSC
01NCB code
692-2313Item number
NIIN 01-692-2313
- Unit price
- $50.50
- Unit of issue
- FT
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 16488
- PINC
- 0016488
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-DEC-20
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- ESD/EMI code
- A
- Schedule B export code
- 8548900100
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DF | J | SMS | FT | 0.0000 | $50.50 | 1 | U | 0 | N | SF9---N | $0.00 | F |
| 01-OCT-2026 | DS | J | SMS | FT | 0.0000 | $50.50 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| SPECIAL FEATURES | CABLES SHALL BE TWISTED IN A LEFT-HAND UNIDIRECTIONAL LAY; USEFUL LIFE - CABLE SHALL BE DESIGNED FOR A COMBINED STORAGE AND OPERATING LIFE OF 10 YEARS. PERIODS OF OPERATION AND STORAGE WILL BE INTERMIXED. |
|---|---|
| MATERIAL DOCUMENT AND CLASSIFICATION | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS MIL SPEC ALL MATERIAL RESPONSES -IL-W-81044 TO 12 |
| MATERIAL DOCUMENT AND CLASSIFICATION | SECOND POSITION JACKET ALL CONDUCTORS MIL SPEC ALL MATERIAL RESPONSES -IL-W-81044 TO 12 |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE, ELECTRICAL, MULTICONDUCTOR, 600 VOLTS |
| ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 22 |
| STRAND AWG SIZE PER CONDUCTOR | 34 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 14 |
| VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0 |
| CROSS-SECTIONAL SHAPE STYLE | |
| OUTSIDE DIAMETER | ALL CONDUCTORS INCHES MAXIMUM 0.320 |
| END ITEM IDENTIFICATION | LINK 16, B-52 |
| CONDUCTOR QUANTITY | 14 |
| MATERIAL | FIFTH POSITION SHIELD FOIL CABLE COPPER |
| MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYALKENE |
| MATERIAL | FOURTH POSITION SHIELD BRAID METALLIC CABLE COPPER |
| MATERIAL | SECOND POSITION JACKET ALL CONDUCTORS PLASTIC POLYVINYLIDENE FLUORIDE |
| MATERIAL | SEVENTH POSITION TAPE CABLE PLASTIC POLYESTER |
| MATERIAL | SIXTH POSITION SHIELD BRAID METALLIC CABLE COPPER |
| MATERIAL | THIRD POSITION TAPE CABLE PLASTIC POLYESTER |
| MATERIAL DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS MIL SPEC ALL MATERIAL RESPONSES -IL-W-81044 TO 12 |
| STRAND QUANTITY PER CONDUCTOR | 19 |
| CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| SURFACE TREATMENT | SIXTH POSITION SHIELD BRAID METALLIC CABLE TIN |
| SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | CORE CONDUCTOR ALL CONDUCTORS MIL SPEC ALL TREATMENT RESPONSES -IL-W-81044 TO 12 |
| SURFACE TREATMENT | FOURTH POSITION SHIELD BRAID METALLIC CABLE TIN |
| SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| PROPRIETARY CHARACTERISTICS | PACS |
| MATERIAL | EIGHTH POSITION JACKET CABLE PLASTIC POLYESTER |
| MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
MOE rules
- MOE rule
- FXGX
- MOE CD
- DF
- AMC
- 3
- AMSC
- C
- Date assigned
- 01-DEC-20
- IMC
- Z
- IMCA
- SX
- PICA
- GX
- PICA LOA
- 01
- SICA
- SX
- SICA LOA
- 5D
- Auth collab
- GX TU
Service data
Air Force
- Fund
- SF
- Budget
- 9
- PVC
- N
- ERRC
- N
Freight
- ACTY CD
- SX
- NMFC
- 030310
- NMFC sub
- Z
- Uniform freight class
- 15080
- Less than truckload
- W
- Water commodity code
- 743
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- CABLE OR WIRE
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- 60C0
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- AAAQuantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
- Method of preservation
- 10Physical protection
- Clng drying
- 1Any suitable process that is not injurious to the item.
- Pres mat
- 00No requirement
- Wrap mat
- 00No requirement
- Cush dun
- NAPPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
- THK
- C3/4 inch thick
- Unit cont
- E5ASTM D5118/D5118M, fiberboard box.
- PKG data source
- P
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- E5ASTM D5118/D5118M, fiberboard box.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
Packaging instructions
- PICA SICA
- P
- PKG design ACTY
- 13873
- SPI date
- 25113
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 01-DEC-2020
- NIIN status code
- 0
Request a quote