Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
01NCB code
699-0717Item number
NIIN 01-699-0717
Request a quote
Unit price
$424.45
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
05-JAN-22
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8544606000
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSFT0.0000$424.45VY09B-----$0.00N
01-OCT-2026DSJSMSFT0.0000$424.45VY0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
8288900 / REV C ITEM 3053711
NAVAL SEA SYSTEMS COMMAND
AD9DZZK
MIL-DTL-24643/67A (SH) AMD 153711
NAVAL SEA SYSTEMS COMMAND
AD9DZZK
M24643/67-04UO7A280
MURRAY BENJAMIN ELECTRIC COMPANY LLC
A59DZZB
M24643/67-04UO81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MIL-DTL-24643/67-04UO81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59FZZB
MIL-DTL-24643/6781349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

TEMP RATINGCELSIUS -20.0 AND CELSIUS 105.0
CROSS SECTION OUTSIDE DIAMETERMILLIMETERS MINIMUM 17.3736 AND MILLIMETERS MAXIMUM 18.6182
ENVIRONMENTAL PROTECTIONWATERPROOF AND FIRE RESISTANT
END ITEM IDENTIFICATIONE-STREAM RAS CONTROL SYSTEM INTERFACE
USAGE DESIGNPOWER
CONDUCTOR QUANTITY3
PART NAME ASSIGNED BY CONTROLLING AGENCYCABLE, ELECT, -20 C TO +105 C, 1000 V, TYPE LS3OW-14
ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 9 (CLASS B)
VOLTAGE RATINGALL CONDUCTORS MAXIMUM PEAK OPERATING VOLTAGE 3000.0
SPECIAL FEATURESCONSTRUCTION (WATERTIGHT WITH CIRCUIT INTEGRITY): FIRST - COPPER CONDUCTOR, COATED OR UNCOATED; SECOND - THERMOSET INSULATION, EXTRUDED OR TAPED; THIRD - OPTIONAL GLASS BRAID; FOURTH - OPTIONAL COVERING, UNLESS REQUIRED; FIFTH - THREE CONDUCTORS SHALL BE CABLED TOGETHER TO FORM A FIRM WELL-ROUNDED ASSEMBLY WITH A LAY NOT LESS THAN 8 OR GREATER THAN 16 TIMES THE CABLED DIAMETER. STANDARD IDENTIFICATION CODE APPLIED BY METHOD 1, 3, OR 5. FILLERS MAY BE USED AS NECESSARY TO FORM A FIRM WELL-ROUNDED ASSEMBLY; SIXTH - ALUMINUM FOIL/POLYESTER TAPE/ALUMINUM FOIL. 0.002-INCH THICK WITH 45 PERCENT OVERLAP; SEVENTH - BRAIDED SHIELD OF TIN COATED COPPER. AWG AND COVERAGE AS NECESSARY TO COMPLY WITH SHIELD PERFORMANCE REQUIREMENTS; EIGHTH - AN OPTIONAL BINDER; NINTH - CROSS-LINKED POLYOLEFIN. INSULATION RESISTANCE (MEGOHMS): 500. CONDUCTOR RESISTANCE PER 1000 FEET AT 25 C (OHMS): 0.859.
MATERIALNINTH POSITION JACKET PLASTIC POLYOLEFIN
MATERIAL DOCUMENT AND CLASSIFICATIONNINTH POSITION JACKET MIL SPEC ALL MATERIAL RESPONSES -IL-DTL-24643 TO 67A (SH) A-D 1
PROPRIETARY CHARACTERISTICSPACS
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION -IL-DTL-24643 TO 67A (SH) A-D 1

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
T
Date assigned
01-JAN-22
IMC
Z
IMCA
HD
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX

Service data

Navy

COG
9B

Freight

ACTY CD
HD
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
43A0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
ZZZ
Special requirement: see the specific drawing or instruction provided
Method of preservation
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
Clng drying
Z
Special requirements - See specific instructions or drawings provided.
Pres mat
ZZ
Special requirement – See specific instructions or drawings provided
Wrap mat
ZZ
Special requirements – see specific instructions or drawings provided
Cush dun
ZZ
Special requirements.
THK
Z
Special requirements – See specific instructions or drawings provided
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
ZZ
Special requirements
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
Z
Special requirement.
Lvl b
Z
Special requirement.
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0000
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
PACKAGING AND PRESERVATION

Packaging instructions

PICA SICA
P
PKG design ACTY
13873
SPI date
21145

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
05-JAN-2022
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.