Catalog item

AMMETER

6625FSC
00NCB code
059-4402Item number
NIIN 00-059-4402
Request a quote
Unit price
$212.70
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16450
PINC
0016450
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-61
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
9030908030

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2026DFJSMSEA0.0000$212.701U0NSF9TG-N$0.00F
01-OCT-2026DSJSMSEA0.0000$212.701U0N-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
621555026
SIMPSON ELECTRIC COMPANY, INC.
A59ETX1B
1227-621555026
SIMPSON ELECTRIC COMPANY, INC.
A59ETX1B
1227-0621555026
SIMPSON ELECTRIC COMPANY, INC.
A39ETX
0621555026
SIMPSON ELECTRIC COMPANY, INC.
A52ETX

Characteristics

STYLE DESIGNATOR
MATERIALPLASTIC
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
COLORBACKGROUND SINGLE INDICATOR SINGLE RANGE WHITE
MOUNTING FACILITY TYPE AND QUANTITYTHREADED STUD(S) 4
SCALE GRADUATION TYPESINGLE INDICATOR SINGLE RANGE LINEAR
MEASUREMENT RANGESINGLE INDICATOR SINGLE RANGE MILLIAMPERES, DC 0.0 TO 20.0
CIRCUIT CONSTRUCTION TYPENONELECTRONIC
MOUNTING STUD DIAMETERINCHES NOMINAL 0.112
FEATURES PROVIDEDZERO ADJUSTER
MOVEMENT SUSPENSION METHODJEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITYTHREADED STUD 2
SPECIAL FEATURESRUGGEDIZED
CIRCUIT CURRENT FOR WHICH DESIGNEDDC
OVERALL LENGTHINCHES NOMINAL 2.240
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHINCHES NOMINAL 1.880
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHINCHES NOMINAL 1.880
OVERALL HEIGHTINCHES NOMINAL 2.470
OVERALL WIDTHINCHES NOMINAL 2.470
SCALE DIVISION QUANTITY40
MOUNTING STUD LENGTHINCHES NOMINAL 0.540
ENVIRONMENTAL PROTECTIONSHOCK RESISTANT AND VIBRATION RESISTANT
FURNISHED ITEMS AND QUANTITYNUT 2
FSC APPLICATION DATATEST SET,ELECT. EQUIP.
INSTALLATION DESIGNPANEL
MOUNTING ARRANGEMENT STYLE
DIAL SCALE MARKING COLORSINGLE INDICATOR SINGLE RANGE BLACK
ACCURACY IN PERCENTSINGLE INDICATOR SINGLE RANGE AT FULL SCALE -2.0 TO 2.0
POINTER COLORSINGLE INDICATOR SINGLE RANGE BLACK
POWER SOURCEEXTERNAL
PANEL FOR WHICH DESIGNEDMAGNETIC OR NONMAGNETIC
METER DEPTH BEHIND MOUNTING FLANGEINCHES NOMINAL 1.060
METER BODY DIAMETER BEHIND MOUNTING FLANGEINCHES NOMINAL 2.170
MOVEMENT TYPEMOVING COIL, PERMANENT MAGNET
INDICATOR TYPEDIAL W/POINTER

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabFmr MOE rl
YD01YD01-SEP-16YD81YD
ZG01ZG01-APR-91ZG81ZG
ZR01ZR01-APR-91ZR81ZR
FGGXDF3D01-APR-06ZTGGX01TG5DTU GXFGTX

Service data

Air Force

Fund
SF
Budget
9
MMAC
TG
PVC
N
ERRC
N

Freight

ACTY CD
XX
NMFC
136750
NMFC sub
X
Uniform freight class
00000
Less than truckload
H
Water commodity code
657
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELECTRIC, IN BOXES

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
05-NOV-1972
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.