Catalog item

VOLTMETER

6625FSC
00NCB code
077-2733Item number
NIIN 00-077-2733
Request a quote
Unit price
$2,086.75
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16449
PINC
0016449
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-63
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
9030908030
FedMall
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeManagement controlNet priceUSC
01-OCT-2026DNJSMSEA0.0000$2,086.751U09B-----$0.00N
01-OCT-2026DSJSMSEA0.0000$2,086.751U0-------$0.00I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
121-1833005
JEWELL INSTRUMENTS LLC
A32AZZ
B80032607342
NAI TECHNOLOGIES INC
H59ETX1B

Characteristics

FEATURES PROVIDEDZERO ADJUSTER
SCALE SELECTION METHODTERMINAL
MOUNTING STUD DIAMETERINCHES NOMINAL 0.138
MEASUREMENT RANGESINGLE INDICATOR SECOND RANGE VOLTS, ROOT MEAN SQUARE -10.0 TO 10.0
SPECIAL FEATURESRUGGEDIZED
COLORBACKGROUND SINGLE INDICATOR ALL RANGES WHITE
SPECIAL MARKINGSON BACK,G AT TOP OF THIRD TERMINAL
MATERIALSTEEL
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
SURFACE TREATMENTPAINT
STYLE DESIGNATOR
FSC APPLICATION DATATEST SET,ELECT. EQUIP.
DIAL SCALE MARKING COLORSINGLE INDICATOR ALL RANGES BLACK
ACCURACY IN PERCENTSINGLE INDICATOR ALL RANGES AT FULL SCALE -1.0 TO 1.0
SCALE GRADUATION TYPESINGLE INDICATOR ALL RANGES LINEAR
MEASUREMENT RANGESINGLE INDICATOR FIRST RANGE VOLTS, ROOT MEAN SQUARE -3.0 TO 3.0
CIRCUIT CURRENT FOR WHICH DESIGNEDDC
DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS1500.0
OVERALL LENGTHINCHES MAXIMUM 1.830
SCALE DIVISION QUANTITY20
SCALE DIVISION QUANTITY68
MOUNTING STUD LENGTHINCHES NOMINAL 0.490
METER DEPTH BEHIND MOUNTING FLANGEINCHES MAXIMUM 1.150
METER BODY DIAMETER BEHIND MOUNTING FLANGEINCHES MAXIMUM 3.570
MOVEMENT TYPEMOVING COIL, PERMANENT MAGNET
POINTER COLORSINGLE INDICATOR ALL RANGES BLACK
POWER SOURCEEXTERNAL
MOUNTING FACILITY TYPE AND QUANTITYTHREADED STUD(S) 6
MOUNTING ARRANGEMENT STYLE
SENSITIVITY RATINGMICROAMPERES 50.0
INSTALLATION DESIGNPANEL
FURNISHED ITEMS AND QUANTITYNUT 6; LOCKWASHER 6; SEAL 1
INDICATOR TYPEDIAL W/POINTER
ENVIRONMENTAL PROTECTIONAIRTIGHT AND DUST RESISTANT AND FUNGUS RESISTANT AND HEAT RESISTANT AND HUMIDITY RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT AND WATER RESISTANT
MOVEMENT SUSPENSION METHODJEWEL PIVOT BASE
CIRCUIT ATTACHMENT METHOD AND QUANTITYSCREW 2 AND SOLDER LUG 2 AND TURRET 1
OVERALL DIAMETERINCHES MAXIMUM 4.580
MOUNTING BOLT CIRCLE DIAMETERINCHES NOMINAL 4.075

MOE rules

MOE rule
N9BN
MOE CD
DN
AMC
1
AMSC
L
Date assigned
01-APR-06
IMC
Z
IMCA
KE
PICA
GX
PICA LOA
01
SICA
GH
SICA LOA
5D
Auth collab
GX
Supp collab
KE GT
Fmr MOE rl
N9ND

Service data

Navy

COG
9B

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
657
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
VZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
42
Container, watervaporproof bag, heat sealed, container
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
ZZ
Special requirement – See specific instructions or drawings provided.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
0.1000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
IP025: PACKAGING, MARKING,

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
05-NOV-1972
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.