Catalog item

VOLTMETER

6625FSC
00NCB code
088-6650Item number
NIIN 00-088-6650
Request a quote
Unit price
$2,580.54
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
16449
PINC
0016449
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
24-DEC-67
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
9030908030

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
Y
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$2,580.54
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
103-205627197
METERMASTER INC METERMOD DIV
R395TX4D
C1022-181755
LOCKHEED MARTIN CORPORATION DIV LOCKHEED MARTIN AERONAUTICS COMPANY
A725SE3D
103-205600638
TRIO LABORATORIES INC
H595TU3B

Characteristics

MOVEMENT TYPEMOVING IRON VANE
POINTER COLORSINGLE INDICATOR ALL RANGES BLACK
POWER SOURCEEXTERNAL
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
SCALE GRADUATION TYPESINGLE INDICATOR ALL RANGES LINEAR
FSC APPLICATION DATATEST SET,ELECT. EQUIP.
METER DEPTH BEHIND MOUNTING FLANGEINCHES NOMINAL 3.750
METER BODY WIDTH BEHIND MOUNTING FLANGEINCHES NOMINAL 5.700
COLORBACKGROUND SINGLE INDICATOR SINGLE RANGE WHITE
NUCLEAR HARDNESS CRITICAL FEATURENONHARDENED
STYLE DESIGNATOR
OPERATING VOLTAGE RATING IN VOLTSAC MINIMUM 105.0 AND AC MAXIMUM 125.0
PHASESINGLE
MEASUREMENT RANGESINGLE INDICATOR FIRST RANGE VOLTS, AC 0.0 TO 0.1
MEASUREMENT RANGESINGLE INDICATOR FOURTH RANGE VOLTS, AC 0.0 TO 3.0
MEASUREMENT RANGESINGLE INDICATOR SECOND RANGE VOLTS, AC 0.0 TO 0.3
MEASUREMENT RANGESINGLE INDICATOR SEVENTH RANGE VOLTS, AC 0.0 TO 100.0
MEASUREMENT RANGESINGLE INDICATOR SIXTH RANGE VOLTS, AC 0.0 TO 30.0
MEASUREMENT RANGESINGLE INDICATOR THIRD RANGE VOLTS, AC 0.0 TO 1.0
SCALE SELECTION METHODSWITCH
METER BODY HEIGHT BEHIND MOUNTING FLANGEINCHES NOMINAL 3.780
CIRCUIT ATTACHMENT METHOD AND QUANTITYSOLDER LUG 2
SCALE DIVISION QUANTITY100
SCALE DIVISION QUANTITY60
FREQUENCY RATINGHERTZ MINIMUM 50.000 AND HERTZ MAXIMUM 60.000
INDICATOR TYPEDIAL W/POINTER
INSTALLATION DESIGNPANEL
MOUNTING ARRANGEMENT STYLE
DIAL SCALE MARKING COLORSINGLE INDICATOR SINGLE RANGE BLACK
MEASUREMENT RANGESINGLE INDICATOR EIGHTH RANGE VOLTS, AC 0.0 TO 300.0
MEASUREMENT RANGESINGLE INDICATOR FIFTH RANGE VOLTS, AC 0.0 TO 10.0
CIRCUIT CURRENT FOR WHICH DESIGNEDAC
OVERALL LENGTHINCHES NOMINAL 4.000
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHINCHES NOMINAL 6.000
ACCURACY IN PERCENTSINGLE INDICATOR ALL RANGES AT FULL SCALE -2.0 TO 2.0
MOUNTING HOLE DIAMETERINCHES NOMINAL 0.138
OVERALL WIDTHINCHES NOMINAL 6.656
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHINCHES NOMINAL 3.000
OVERALL HEIGHTINCHES NOMINAL 4.156

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collabSupp collabFmr MOE rl
YC01YC01-AUG-24YC81YC
DGX1DS3C01-JUL-05GX01GXTXDTX1

Freight

ACTY CD
SE
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
657
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
VZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
69F0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
41
Watervaporproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
NA
PPP-C-795, closed cell plastic cushioning; or A-A-3129, open cell plastic cushioning; or PPP-C-1797, polypropylene...
THK
C
3/4 inch thick
Unit cont
EC
ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
DO
Any suitable fiber box included in this table may be used (see J.4.9.1).
Lvl A
Q
Packing shall be accomplished in accordance with table C.II for the packing level specified.
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
U
Items or packages that require packing for acceptance by the carrier shall be packed in exterior type shipping...
Unit pack weight
3.7000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.2190
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.

Packaging instructions

PICA SICA
P
PKG design ACTY
14933
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
04-NOV-1976
NIIN status code
0

Request a quote