Catalog item

RESISTOR,DECADE

6625FSC
00NCB code
445-3329Item number
NIIN 00-445-3329
Request a quote
Unit price
$36,609.00
Unit of issue
EA
Source of supply
FLZ
DEMIL code
A

Identification

Item name code
00491
PINC
0000491
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
7
NIIN assigned
21-DEC-70
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
9030908030
IUID indicator
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
03-AUG-2026DFJFLZEA0.0000$36,609.001U0S--MRH-N$0.00L
03-AUG-2026DNJNRPEA0.0000$52,575.001U0H7Z--003$8,542.00N

Part numbers

Part number
720A
CAGE
89536
FLUKE CORP
CAGE status
A
RNCC
3
RNVC
2
Document availability code
4
RNAAC
MB
RNFC
3
RNSC
D

Characteristics

TEMP COEFFICIENT OF ELECTRICAL VALUE IN PPM PER DEG CELSIUS-0.5 TO 0.5
PANEL MATERIALALUMINUM
TERMINAL TYPE AND QUANTITYPHONE JACK 6
ELECTRICAL INCREMENT VALUE PER SECTIONKILOHMS 2.000 AND KILOHMS 10.000 AND OHMS 400.000 AND OHMS 400.000 AND OHMS 400.000 AND OHMS 400.000 AND OHMS 400.000
BASIC SHAPE STYLE
MOUNTING TYPEPANEL
MAXIMUM OPERATING TEMPCELSIUS 30.0
MATERIALCASE ALUMINUM
ADJUSTMENT METHODROTARY SWITCH
DIAL TYPEDRUM DIAL
INDIVIDUAL SECTION QUANTITY7
FUNCTIONAL CLASSIFICATIONAA-10.1
SPECIAL FEATURESACTION ID 45573495
OVERALL LENGTHINCHES NOMINAL 19.000
OVERALL HEIGHTINCHES NOMINAL 5.250
OVERALL WIDTHINCHES NOMINAL 8.400
ENVIRONMENTAL PROTECTIONDUSTPROOF AND MOISTURE PROOF AND MAGNETIC SHIELDING
MAXIMUM VOLTAGE RATING IN VOLTSAC 700.0
SUPPLEMENTARY FEATURESMANUFACTURERS NAME: VOLTAGE DIVIDER

MOE rules

MOE ruleMOE CDAMCAMSCNIMSCDate assignedIMCPICAPICA LOASICASICA LOAAuth collabSupp collabDSORFmr MOE rl
WG01WG01-OCT-17WG81WG
WS01WS01-MAR-24WS81WS
YA01YA01-AUG-00YA81YA
YB01YB01-APR-91YB81YB
YD01YD01-SEP-16YD81YD
YJ01YJ01-APR-91YJ81YJ
YW01YW01-MAR-95YW81YW
ZB01ZB01-DEC-99ZB81ZB
ZC01ZC01-APR-91ZC81ZC
ZF01ZF01-APR-91ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZH01ZH01-APR-91ZH81ZH
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-NOV-97ZP81ZP
ZT01ZT01-APR-91ZT81ZT
ZS01ZS01-APR-91ZS81ZS
ZU01ZU01-APR-08ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
ZX01ZX01-JUN-02ZX81
FGG4DF3ZF01-SEP-00DTG22TUFRFEE4
VJ01VJ01-FEB-19VJ81VJ
NSGSDN3Z101-SEP-00DTG22HD8DHD TUGGJANSES

Management phrases

Major organizational entity
DF
USC
L
Phrase code
R
Phrase
REFER TO P015333103
Quantity per assembly
0
Technical document
P015333103

Service data

Navy

COG
7Z
IRRC
00
SMCC
3

Air Force

Budget
M
MMAC
RH
PVC
N
ERRC
S

Freight

ACTY CD
ZF
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
738
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HQ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICAPKG catUnpackaged weightUnpackaged widthUnpackaged lengthUnpackaged heightUnit of issueTOSIntermediate container qtyMethod of preservationClng dryingPres matWrap matCush dunTHKUnit contPKG data source
PZZZ00.00000.0000.0000.000EAB000
No intermediate container quantity specified (000)
33
Greaseproof-waterproof bag, heat sealed
1
Any suitable process that is not injurious to the item.
00
No requirement
XXXXXNV
PPP-B-1672, Type III, telescoping encapsulated cushioning in reusable box.
P
SZZZ018.000019.00014.0005.000EAB000
No intermediate container quantity specified (000)
DW
Preserve by Method 52 as follows: Item shall be cleaned, wrapped, blocked and braced, with desiccant in an interior...
1
Any suitable process that is not injurious to the item.
00
No requirement
K3
MIL-PRF-81705, Type III, Class 1, transparent, electrostatic protective, static shielding, barrier material or...
GH
MIL-PRF-26514, Type I, Class 2, Grade C, flexible polyurethane foam, heavy load range
H
2 inches thick
NZ
NAVICP Drawing No.
A

Unit pack

PICA SICASPC MKGInter contUCLLvl ALvl bLvl cUnit pack weightUP SZ MAXBUP SZ MAXLUP SZ MAXHUnit pack cubeOPISupplemental instructions
P17
Reusable container
00
No requirement.
B
Unit container provides level B packing protection.
40.000026.5000036.5000019.0000010.6350M
All packaging data is mandatory for compliance and no substitutions are permitted.
S39
ESD sensitive electronic device requirements of MIL-STD-129 apply
00
No requirement.
A
Unit container provides level A packing protection.
F
Packing is not required: the unit container shall also serve as the shipping container.
F
Packing is not required: the unit container shall also serve as the shipping container.
F
Packing is not required; the unit container shall also serve as the shipping container.
300.000028.0000035.0000020.5000011.6260M
All packaging data is mandatory for compliance and no substitutions are permitted.
ZZ = MIL-R-39032

Packaging instructions

PICA SICASPI noSPI dateContainer NSN
PF000002XE9891778115-01-015-1314
S000008145-01-262-2987

Full packaging code breakdown

Related items

Standardization

Item standardization code
5
Orig stdzn dec
98
Dt stdzn dec
01-FEB-1975
NIIN status code
0

Request a quote